DC-21 functional specifications include:
|
Input
|
|
Number of Channels
|
2 analog channels
1 syncronization channel
|
|
Input types
|
ICP® or charge accelerometer (2 ch.)
Linear voltage (2 ch.)
Phase reference tacho (TTL)
|
|
Sensor types
|
accelerometer, current clamps,
microphone,
tacho probe
|
|
Integration
|
analog (1 stage),
digital (1 or 1 stages)
|
|
Frequency range
|
0.1 - 25600 Hz
|
|
Frequency range (+0.5dB)
|
0.5 - 25600 Hz
|
|
Linear input signal range
|
+\- 3 V
|
|
Phase difference between channels
|
in 2..300 Hz 1 degree or less
in 301..1000Hz 5 degres or less
|
|
Between channel interference
|
- 100 dB or better
|
|
Gain
|
AUTO, 0-54 dB in 6 dB steps
|
|
| Vibration parameters |
| Measured magnitudes |
displacement, velocity, acceleration, peak-factor |
| Detector |
RMS, true peak, peak-peak |
| Frequency bands for vibration |
| ISO standard: | 2..1000, 10..1000, 10..2000 Hz | |
| additional: | 2..200, 3..300, 5..500, 10..5000, 500..2500, 625..1250, 1200..2500, 2500..5000, 5000..10000, 10000..25000, 17000..25000 Hz | |
| Vibration range |
acceleration (on 160 Hz) from 0.05 up to 1000 m/s2
velocity (on 80 Hz) from 0.1 up to 100 mm/s
displacement (on 40 Hz) from 1 up to 1000um
|
|
|
FFT spectra
|
|
Frequency span
|
25, 50, 100, 200, 400, 800, 1600,
3200, 6400, 12800, 25600 Hz
|
|
Frequency resolution
|
400, 800, 1600 lines
|
|
Dynamic range
|
90 dB or better
|
|
Linear averages
|
1-256
|
|
Weighting function
|
Hanning
|
|
Scale Type
|
Linear or logarythmic
|
|
Envelope
detector
Band pass filters
with center frequencies
|
|
1/3 octave:
|
800, 1000,
1250, 1600, 2000, 2500, 3200, 4000, 5000,
6400, 8000, 10000, 12800, 16000, 20000 Hz
|
|
|
1/1 octave:
|
50, 100, 200, 400, 800, 1600, 3200, 6400, 8000, 12800, 16000 Hz
|
|
|
|
Time
waveform
|
|
Sampling frequencies
|
64, 128, 256, 512, 1024, 2048,
4096, 8192, 16384, 32768, 65536 Hz
|
|
Number of samples
|
200, 400, 1000, 2000, 4000
|
|
Envelope
detector
Band pass filters
with center frequencies
|
|
1/3 octave:
|
800, 1000,
1250, 1600, 2000, 2500, 3200, 4000, 5000,
6400, 8000, 10000, 12800, 16000, 20000 Hz
|
|
|
1/1 octave:
|
50, 100, 200, 400, 800, 1600, 3200, 6400, 8000, 12800, 16000 Hz
|
|
|
|
Amplitude
and Phase measurements
|
|
Frequency range
|
0.5-1700 Hz (30-102000 RPM)
|
|
RPM error
|
+ 1%
|
|
Phase measurement
error
|
+ 5 degrees
|
|
Amplitude error
|
+ 1 dB
|
|
Automatic control
|
tacho signal parameters
reliability of measurements
|
|
Amplitude measurement
units
|
G, m/s2,
mm/s, mm, in/s2,
in/s, mil
RMS, Peak, or Peak to Peak
|
|
Internal power supply
for
phase reference tacho
|
5 V DC, 15 mA
|
|
|
Overall Measurements
|
|
Bands
|
2-1000 Hz, 10-1,000 Hz, 10-20,000 Hz, 10-5,000 Hz,
5-10 kHz,10-25 kHz, 2-200 Hz, 5-500 Hz
|
|
Detector Type
|
RMS, Peak, Peak to Peak, Peak Factor
|
|
Scale Type
|
Linear or log
|
|
Units
|
g, m/s^2, mm/s, mm, V, in/s,
mils
|
|
|
RPM-amplitude-frequency measurements for run-up/coast-down
|
|
Rotation speed range
|
0.5-1700 Hz (30-102000 RPM)
|
|
Frequency range
|
from 0.5 Hz up to 10xRPM
|
|
RPM resolution
|
up to 200 lines on two harmonics
|
|
Measurements are done on
|
1-6th harmonics of rotation speed
|
|
|
|
General
|
|
Operation Temperature
|
-20 / +50C (5/ 120F)
|
|
Weight
|
0.9 kg
|
|
Dimensions
|
109(W) x 208(L) x 35(H) mm
|
|
Battery type
|
Nickel Metal Hydride
|
|
Operation time from
batteries
|
10 hours with reserve battery
|
|
Battery full charge
time
|
2 hours
|
|
Power management
|
Adjustable auto shut down
Adjustable auto backlight switch off
|
|
Data storage capacity
|
800 spectra
|
|
Interfaces
|
RS-232
|
|
|
|
|
|
|
|