Input
|
|
Number of Channels
|
2
|
|
Continuous measurements
|
Continuously updated every 1 second on each channel
|
|
Transducer types
|
ICP® accelerometer
|
|
Integration
|
up to 1 stage analog 1 or 2 stages digital
|
|
|
Vibration parameters |
Measured magnitudes |
displacement, velocity, acceleration, peak-factor |
Detector |
RMS, true peak, peak-peak |
Frequency bands for vibration |
ISO standard: |
2..1000, 10..1000, 10..2000 Hz | |
|
additional: | 2..200, 3..300, 5..500, 10..5000, 5000..10000, 10000..25000, 17000..25000, 500..2500, 600..1250, 1250..2500, 2500..5000 Hz | |
Vibration range |
acceleration from 0.02 up to 1000 m/s2
velocity from 0.01 up to 1000mm/s
displacement from 0.1 up to 10000um
|
|
Scale Type
|
Linear or log
|
|
Units
|
g, m/s2, mm/s, um, V, in/s,
mils
|
|
|
Alarming and indication
|
|
Alarm levels
|
Low signal 4 condition zones divided by thresholds for
|
|
Thresholds
|
Programmable
|
|
Indication
|
Numerical Color Bar graphs within each condition zone
|
|
Relay lines
|
2 independent for each channel
|
|
Relay operation algorithm
|
custom programmable
|
|
Relay commutation
|
1 A maximum current 150V DC or 250V AC
|
|
|
Analog output
|
|
For control systems
|
4-20 mA for each channel
|
|
For condition monitoring, diagnostics
|
-3 .. +3 V linear output from accelerometers
|
|
|
Integration in the information system of the enterprise
|
|
Interface
|
RS-485 industry standard
|
|
Supported protocol
|
MODBUS RTU
|
|
Software technology
|
OPC Server
|
|
|
General
|
|
Operation Temperature
|
0 / +50C
|
|
Dimensions
|
115 x 90 x 60 mm
|
|
Power supply required
|
10..40V DC
|